I’m not happy, could any pros point out errors please?
10/19/2020
I'd prefer to see the wall flashing go behind whatever the covering is on the wall and then come out over the metal panel and lock over a Z Cleat put on top of the metal panel alongside the wall.
Isaiah Industries, Inc.
10/19/2020
10/19/2020
10/19/2020
As you're probably aware, those panels are lapped backwards. The panel with the horizontal leg should be on the bottom.
Isaiah Industries, Inc.
10/19/2020
Thanks Todd, I’ve got some more photos of the install coming for your expert evaluation. I greatly appreciate it